Add subprocess liveness monitor to detect scheduler crashes (#18582)

Co-authored-by: 继优 <jiyou.ljy@alibaba-inc.com>
Co-authored-by: shuwenn <47200617+alphabetc1@users.noreply.github.com>
This commit is contained in:
Simon (Jiyou) Li
2026-03-29 00:09:13 -07:00
committed by GitHub
co-authored by 继优 shuwenn
parent 35f5a0ff35
commit 22e4733ab9
7 changed files with 300 additions and 29 deletions
@@ -0,0 +1,137 @@
# Copyright 2023-2024 SGLang Team
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
# ==============================================================================
"""Tests for SubprocessWatchdog in watchdog.py"""
import multiprocessing as mp
import os
import signal
import threading
import time
import unittest.mock
from sglang.srt.utils.watchdog import SubprocessWatchdog
from sglang.test.ci.ci_register import register_cpu_ci
from sglang.test.test_utils import CustomTestCase
register_cpu_ci(est_time=10, suite="stage-a-cpu-only")
def healthy_worker():
time.sleep(10)
def crashing_worker():
os._exit(1)
def slow_crash_worker(delay: float = 0.5):
time.sleep(delay)
os._exit(42)
class TestSubprocessWatchdog(CustomTestCase):
def setUp(self):
self.sigquit_triggered = threading.Event()
self._procs = []
self._monitor = None
original_kill = os.kill
def mock_kill(pid, sig):
if sig == signal.SIGQUIT:
self.sigquit_triggered.set()
else:
original_kill(pid, sig)
self._patcher = unittest.mock.patch("os.kill", side_effect=mock_kill)
self._patcher.start()
def tearDown(self):
if self._monitor is not None:
self._monitor.stop()
self._patcher.stop()
for p in self._procs:
if p.is_alive():
p.terminate()
p.join(timeout=1)
def _spawn(self, target, args=()):
proc = mp.Process(target=target, args=args)
proc.start()
self._procs.append(proc)
return proc
def _watch(self, procs, names=None, interval=0.1):
if not isinstance(procs, list):
procs = [procs]
self._monitor = SubprocessWatchdog(
processes=procs,
process_names=names,
interval=interval,
)
self._monitor.start()
return self._monitor
def test_healthy_processes_no_sigquit(self):
proc = self._spawn(healthy_worker)
self._watch(proc)
time.sleep(0.5)
self.assertFalse(self.sigquit_triggered.is_set())
def test_crashed_process_triggers_sigquit(self):
proc = self._spawn(slow_crash_worker, args=(0.2,))
self._watch(proc)
self.assertTrue(
self.sigquit_triggered.wait(timeout=2.0),
"SIGQUIT was not triggered within timeout",
)
def test_immediate_crash_detection(self):
proc = self._spawn(crashing_worker)
self._watch(proc, interval=0.05)
self.assertTrue(
self.sigquit_triggered.wait(timeout=1.0),
"Immediate crash was not detected",
)
def test_multiple_processes_one_crashes(self):
healthy = self._spawn(healthy_worker)
crashing = self._spawn(slow_crash_worker, args=(0.2,))
self._watch([healthy, crashing], names=["healthy", "crashing"])
self.assertTrue(
self.sigquit_triggered.wait(timeout=2.0),
"Crash was not detected when one of multiple processes crashed",
)
def test_empty_processes_list(self):
self._watch([], interval=0.1)
time.sleep(0.3)
self.assertFalse(self.sigquit_triggered.is_set())
def test_normal_exit_no_sigquit(self):
proc = self._spawn(lambda: None)
proc.join(timeout=2)
self._watch(proc)
time.sleep(0.3)
self.assertFalse(
self.sigquit_triggered.is_set(),
"SIGQUIT should not be triggered for normal exit (exitcode=0)",
)
if __name__ == "__main__":
mp.set_start_method("spawn", force=True)
import unittest
unittest.main()